X axis motor replacement

X axis motor replacement

Tools to be prepared

M3, M2.5 hexagonal wrench, 5MM plum wrench

NOTE: Please complete the following operations under power failure and keep the removed screws properly to avoid loss.

Disassembling the X-axis motor

1. Unscrew the two right side belt buckles of the laser head to separate the right side X-axis belt buckle from the laser head.

2. Open the right door on the device


3. Cut the tie wrap and disconnect the power and signal wires from the X-axis motor.


4. Unscrew the “tensioning screw” of the X-axis motor belt.

5. Unscrew the fixing screws of the drag chain groove to facilitate subsequent operations

6. Unscrew the 4 screws in the picture to remove the X-motor module

7. Unscrew the 4 screws that hold the motor in place.

8.You can remove the X-axis motor.

Installing the X-axis motor

1. Install the new X-axis motor and motor belt to the base, but do not lock the set screws.

2. Screw the X-axis motor belt's “tensioning screw” into the base, adjust the tightness of the X-axis belt by tightening the “tensioning screw”, after the adjustment is completed, make sure to tighten the 4 screws fixing the motor.

Attention:

The belt's tightness is not a fixed standard. Note: There is no fixed standard for the tightness of the belt, you can press the Y-axis motor belt to feel the appropriate degree of tightness, as a reference for the adjustment of the Y-axis belt.

The motor belt should not be too tight, or it may rattle.

 

3. Reinstall the X-axis motor module to the X-axis

4. Refasten the drag chain slots

5. Connect the power and signal wires of the X-axis motor and secure the wires with cable ties.


6. Install the X-axis belt to the motor gear correctly

7. Reinstall the X-axis belt buckle onto the slider and adjust the belt to the proper tightness by screwing in the screws to complete the replacement.

Note: There is no fixed standard for the belt tightness, you can press the Y-axis belt to feel the appropriate degree of tightness, as a reference basis for X-axis belt adjustment.


    • Related Articles

    • X-axis motor replacement

      Tools Required M2, M2.5, M3 hexagonal wrenches; M7 open-end spanners; tie wraps; brand new X-axis motor Note: Please complete the following operations in the power-off state, and keep the removed screws properly to avoid losing them Disassembly of ...
    • Y-axis motor replacement

      Tools to be prepared M3 hexagonal wrench*1, new Y-axis motor*1 NOTE: Please complete the following operations under power failure and keep the removed screws properly to avoid loss. Removing the Y-axis motor 1. Open the rear door cover of the unit 2. ...
    • Y-axis motor replacement

      Tools Required M2, M2.5 hexagonal spanner; tie wraps; steel rule; brand new Y-axis motor Note: Please complete the following operations in the power-off state, and keep the removed screws properly to avoid losing them Disassemble the Y-axis motor 1. ...
    • Adjustment of the X-axis

      Tools required M2,3,4 hexagonal wrench*1, 5.5mm open-end wrench*1 Note: Please complete the following operations under power-off condition and keep the removed screws properly to avoid loss. Procedure 1. Adjust the belt (if the belt elasticity is the ...
    • How to connect the Air Purifier-X series

      1.Preparation ①. Consumable preparation One Laser X model device x 1,Air Purifier x 1,Phillips screwdriver x 1 ②. Debug software None 2.Operation step ①.Install the equipment air duct to the air inlet of the purifier Use a cross screwdriver to ...