Trouble Shooting
Adjustment of the X-axis
Tools required M2,3,4 hexagonal wrench*1, 5.5mm open-end wrench*1 Note: Please complete the following operations under power-off condition and keep the removed screws properly to avoid loss. Procedure 1. Adjust the belt (if the belt elasticity is the ...
Laser head without red dot indication -Hydra series
Issue phenomenon: During the operation of the device, no red dot indication is found. Operation Guide: 1.Check whether the red light is operating normally ①.Open the left door of the device ②.Find the red light indicator mounting socket and check ...
OneLaser-Hydra The device emits abnormal light
Issue Phenomenon The device emits abnormal light when it is turned on Fault Cause 1.Device motherboard port plug-in error The laser signal output port of the device is plugged into the wrong terminal Open the side door of the device and find the ...