Replace the control panel

Replace the control panel


Notes
Note:
• Before unplugging the cable, please take a photo to record the connection status to prevent incorrect wiring during reinstallation.
• Keep the removed screws in a safe place to prevent loss.

Tools Required              


Hex wrenches (M2 & M3), Phillips screwdriver                                                                                                                                                                                                                                                            

1.Removing the Machine Enclosure

①.Ensure that the device power is disconnected

②.Use the M2 hex wrench to remove the screws on the rear cover, then take off the cover.                                                                                                                                                                                                                                                                                            ③.Remove the screws on the right-side panel.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               ④.Before removing the right-side panel, disconnect the following cables:

  • Emergency stop switch power cable
  • Touchscreen signal cable
  • PM2.5 detector power cable                                                                                                                                                                                                                                                                                                                                                                                                                             

    2. Remove the control panel

    Use a Phillips screwdriver to unscrew the screws in the picture below to remove the control panel                                                                                                                                                                                                                                                                                                                    

    3. Reinstall the machine

    ①. Re fix the new control panel onto the chassis

    Attention: The signal cable interface of the control panel should face the PM2.5 detector and should not be installed upside down

    ②. Connect the emergency stop switch power cord, control panel signal cord, and PM2.5 detector power cord

    ③. Install the casing and secure it with screws                                                                                                                                                                                                                                           

    • Related Articles

    • Control panel replacement

      Tools that need to be prepared Cross screwdriver Disassemble the control panel Disconnect the power supply of the device Open the front door cover of the device 3. Unscrew the fixing screws of the control panel 4.Remove the control panel and unplug ...
    • Control card replacement

      Note: • Before unplugging the cable, please take a photo to record the connection status to prevent incorrect wiring during reinstallation. • Keep the removed screws in a safe place to prevent loss. Tools Required Hex wrenches (M2 & M3), Phillips ...
    • Control card replacement

      Tools that need to be prepared Door cover key, cross screwdriver Replacement steps 1. Disconnect the power supply of the device 2. Open the lower right door of the device 3. Disconnect all lines on the control board Note: Please take a photo and ...
    • Touchscreen get stucked after turning on

      Issue Phenomenon After turning the machine on, the touch screen panel has been stuck in this page and cannot enter the main interface. Operational Guide Rotary switch are on Please turn off the rotary switch and then try to reboot the machine again. ...
    • One Laser Firmware Upgrade Tutorial Hydra Series

      NOTE: Contact the manufacturer's technician for the latest version of the firmware programme.The HMI firmware (i.e. panel firmware) must be updated before updating the control motherboard. During the firmware update process, please ensure that the ...