Tools Required
Hex wrenches (M2 & M3), Phillips screwdriver
1.Removing the Machine Enclosure
①.Ensure that the device power is disconnected
②.Use the M2 hex wrench to remove the screws on the rear cover, then take off the cover. ③.Remove the screws on the right-side panel.
④.Before removing the right-side panel, disconnect the following cables:
- Emergency stop switch power cable
- Touchscreen signal cable
- PM2.5 detector power cable
Use a Phillips screwdriver to unscrew the screws in the picture below to remove the control panel2. Remove the control panel
3. Reinstall the machine
①. Re fix the new control panel onto the chassis
Attention: The signal cable interface of the control panel should face the PM2.5 detector and should not be installed upside down
②. Connect the emergency stop switch power cord, control panel signal cord, and PM2.5 detector power cord
③. Install the casing and secure it with screws