Based on our testing and research, we recommend adding the two antifreeze solutions recommended in this article to the chiller during winter.                                                                            

Please read the instructions carefully and make adequate preparations before use


1. Turning all machine off (chiller and laser machine), drain water away from chiller and then clean the limescale.

2. Add the water first, then add the antifreeze liquid.

3. Open the chiller, let the water circulate for 5-10 minutes, then you can start work.

Note:

1. Antifreeze fluid can degrade over time, increasing its corrosiveness and altering its viscosity. Regular replacement is essential. We recommend changing the water every 2-3 months at room temperature. When temperatures rise above freezing, circulating cooling water can be replaced with softened water, such as distilled or purified water.

2. Consistency is key: Use the same antifreeze brand. While main components may be similar across brands, additive formulas can vary. Mixing different antifreeze types can lead to chemical reactions, precipitation, or bubbles.

3. For extended periods of non-use, drain the water from the laser tube, water chiller, and water pipes, especially for glass laser tubes. Failure to follow this procedure can result in laser tube damage, which is not covered by warranty.     

 RV Antifreeze

This product should be used undiluted only when necessary. When freezing is not a concern, the system should be flushed and refilled with distilled water. 

Link:

https://www.walmart.com/ip/Super-Tech-RV-and-Marine-Antifreeze/17179674                                                                                                                                                                                            

                                                                                                                                                                                      

Clariant       

We recommend two models from this brand, but they need to be diluted according to the specified ratio.                                                                          

1. Antifrogen N                                                                                                                                                                                                                                                                                                                    https://www.clariant.com/en/Solutions/Products/2013/12/09/18/25/Antifrogen-N

Antifrogen® N is a liquid, tinted pale yellow, for use as a heat transfer medium in closed hot water heating systems, heat pumps and as cooling brine in industrial refrigeration equipment. Antifrogen® N is not suitable for the use in food or pharmaceutical applications. Alternatively, the use of Antifrogen® L is recommended. The product is inhibited without the use of nitrites-, amines-, borates-, silicates- and phosphates. The optimization of the corrosion inhibition system was performed without the use of CMR-substances (cancerogenic, mutagenic, reprotoxic).                                          

2. Antifrogen L                                                                                                                           

  https://www.clariant.com/en/Solutions/Products/2014/06/23/15/46/ANTIFROGEN-L

Antifrogen® L is a clear liquid, tinted blue, for use as a heat transfer medium in heat pump systems and in the food industry, e.g. in breweries, dairies, ice-cream factories, cold stores and fish processing factories. The product is inhibited without the use of nitrites-, amines-, borates-, silicates- and phosphates. The optimization of the corrosion inhibition system was performed without the use of CMR-substances (cancerogenic, mutagenic, reprotoxic).                                                                                                                   

Deployment ratio for Antifrogen                                                                                                                                        

Proportion(Anti-freeze fluid: Distilled water)

Room temperature(Unit:℃)

3:7

-12~-15℃

4:6

-22~-25℃

5:5

-32~-35

6:4

-42~-45

      

 


    • Related Articles

    • OneLaser-Hydra The device emits abnormal light

      Issue Phenomenon The device emits abnormal light when it is turned on Fault Cause 1.Device motherboard port plug-in error The laser signal output port of the device is plugged into the wrong terminal Open the side door of the device and find the ...
    • Maintenance Guide

      Optical Maintenance Tool Requirements Lens cleaner、Q-tip、hex key If the provided cleaning cleaner runs out, we recommend using absolute ethanol to clean the lens. To avoid damaging the lens coating, please do not use isopropyl alcohol. If the ...
    • How to Fill Water Tanks

      Note: To ensure the normal operation of the One Laser XT model, please note that the cold water pump equipped with this device is used to cool the glass tube. The water in the water tank of the water pump has been drained at the factory. If it is ...
    • Connect XT&XRF To LightBurn Via WiFi

      Important Information The WIFI connection can only communicate with the controller, not the camera. WiFi connection is not the most stable method, please choose according to the actual situation. Operation Guide Connect to WiFi Turn on the machine. ...
    • Wifi cannot connect

      Note: To ensure efficient file transfer, please try to avoid WiFi transmission through walls. Issue phenomenon: The machine is working properly but the Wifi cannot connect. Operation Guide 1.Switch configuration error The switch channel setting error ...