Laser replacement

Laser replacement

Notes:

1.Before operation, the power must be disconnected, otherwise there is a risk of electric shock.

2.Please keep the screws that are removed properly to avoid losing them.

Tools Required:

Hex wrench,flathead screwdriver,Phillips screwdriver,door cover key

Glass Tube Replacement

1.Disassembly of Glass Tube

.Remove the water pipe from the outlet, wait for the water in the glass pipe to flow back into the chiller, and then reconnect the water pipe from the outlet

②.Open the upper rear door and the lower left rear door of the equipment.

 

③.Use a steel ruler to measure the distance from the glass tube to Mirror 1 and record it.

④.Disconnect the positive and negative electrode wires:

  1. Rotate the positive electrode terminal counterclockwise.

  1. Use a flathead screwdriver to loosen the screw securing the negative electrode wire.

⑤.Cut the zip ties with a utility knife and remove the inlet and outlet water pipes from the glass tube.

⑥.Use a hex wrench to remove the screws securing the glass tube and then take out the glass tube.

2.Installation of Glass Tube

①.Place the laser on the laser holder and adjust the distance from the laser to Mirror 1 (based on the distance recorded during disassembly).

②.Tighten the tape while securing the laser with screws.

③.Connect the inlet and outlet water pipes to the laser and secure them with zip ties.

④.Reconnect the positive and negative output wires.

RF Tube Replacement

1.Disassembly of RF Tube

①.Open the lower left side door of the equipment.

 

②.Disconnect the power cable, fan power cable, and signal cable.

③.Rotate counterclockwise to unscrew the beam expander, and then use a hex wrench to remove the beam expander mount

④.Remove the four fixing screws of the RF tube and take out the RF tube.

⑤.Use a hex wrench to separate the RF tube from the RF tube holder.

2.Installation of RF Tube

①.Install the beam expander mirror holder onto the new RF tube, and then install the beam expander mirror onto the mirror holder

②.Attach the RF tube holder to the new RF tube.

③.Secure the RF tube inside the machine.

④.Reconnect the RF tube power cable, fan power cable, and communication network cable.

    • Related Articles

    • Laser Replacement

      Note: 1.The following operations should be performed after power disconnection. 2.Please keep the removed screws properly to avoid loss. Disassembly of the Enclosure Both XT and XRF models require disassembly of the casing Use an M2 hex wrench to ...
    • Laser Power Supply Replacement

      Tools Required One screwdriver, Phillips screwdriver, door cover key The laser power supply is installed at the back of the machine. Note: The power must be disconnected before operation to avoid the risk of electric shock. 1. Glass Tube Laser Power ...
    • Laser power supply replacement

      NOTE: ● Please keep the disassembled screws properly to avoid loss ● Before unplugging the cable, please take a photo to record the connection status to preventincorrect wiring during reinstallation. Tools that need to be prepared Hexagonal wrench ...
    • No Laser Beam

      Issue phenomenon The machine works normally but there is no laser output. Causes & Solutions 1.Wrong processing parameters If the speed is too fast and the power is too low, there will be no traces during the engraving process. Please set the correct ...
    • X axis motor replacement

      Tools to be prepared M3, M2.5 hexagonal wrench, 5MM plum wrench NOTE: Please complete the following operations under power failure and keep the removed screws properly to avoid loss. Disassembling the X-axis motor 1. Unscrew the two right side belt ...