Laser replacement

Laser replacement

Notes:

1.Before operation, the power must be disconnected, otherwise there is a risk of electric shock.

2.Please keep the screws that are removed properly to avoid losing them.

Tools Required:

Hex wrench,flathead screwdriver,Phillips screwdriver,door cover key

Glass Tube Replacement

1.Disassembly of Glass Tube

①.Remove the water pipe from the outlet, wait for the water in the glass pipe to flow back into the chiller, and then reconnect the water pipe from the outlet

②.Open the upper rear door and the lower left rear door of the equipment.

 

③.Use a steel ruler to measure the distance from the glass tube to Mirror 1 and record it.

④.Disconnect the positive and negative electrode wires:

  1. Rotate the positive electrode terminal counterclockwise.

  1. Use a flathead screwdriver to loosen the screw securing the negative electrode wire.

⑤.Cut the zip ties with a utility knife and remove the inlet and outlet water pipes from the glass tube.

⑥.Use a hex wrench to remove the screws securing the glass tube and then take out the glass tube.

2.Installation of Glass Tube

①.Place the laser on the laser holder and adjust the distance from the laser to Mirror 1 (based on the distance recorded during disassembly).

②.Tighten the tape while securing the laser with screws.

③.Connect the inlet and outlet water pipes to the laser and secure them with zip ties.

④.Reconnect the positive and negative output wires.

RF Tube Replacement

1.Disassembly of RF Tube

①.Open the lower left side door of the equipment.

 

②.Disconnect the power cable, fan power cable, and signal cable.

③.Rotate counterclockwise to unscrew the beam expander, and then use a hex wrench to remove the beam expander mount

④.Remove the four fixing screws of the RF tube and take out the RF tube.

⑤.Use a hex wrench to separate the RF tube from the RF tube holder.

2.Installation of RF Tube

①.Install the beam expander mirror holder onto the new RF tube, and then install the beam expander mirror onto the mirror holder

②.Attach the RF tube holder to the new RF tube.

③.Secure the RF tube inside the machine.

④.Reconnect the RF tube power cable, fan power cable, and communication network cable.