Issue phenomenon:

During the operation of the device, no red dot indication is found.

Operation Guide:

1. Check whether the red light is operating normally

  • Use an M2 hexagonal wrench to remove the hexagonal nut on the back cover of the laser device and remove the back cover.                                                                                                                                                                                                                                                         
  • Find the red light indicator mounting socket and check whether the red light indicator is working properly (is there a red light?)                                                                                                                                
  • Red light is normal: The reflector may be oxidized/dirty, causing it to fail to reflect red light. Please check and maintain the optical lens.
  • Abnormal red light: Please follow the steps below to troubleshoot.                                                                                                                                                                                    

    2.Red dot indicator interface contact is bad

    • Find the red light indicator adapter interface and check whether it is in poor contact
    Note: The red light indicator adapter interface is located on the back cover of the laser.                                                                                                                                                                                                                                                                                                                                                
  •  Use an M2 hexagonal wrench to remove the hexagonal nut on the right door of the device and remove the right door of the device:                                                                                                                                                                                                                                                                                                               
  • Find the energy saving control panel in the picture below,remove the wires in the figure below, then use a multimeter to measure whether the voltage is 5V, and adjust the gear to DC 5V, as shown in the figure:
    • Normal voltage: If there is 5V voltage, it means that the red light indicator is faulty, please contact us for replacement.
    • Abnormal voltage: If the voltage is not 5v, it means that the TL energy-saving control motherboard is faulty, please contact us for replacement.                                                                                
    • Related Articles

    • Laser head without red dot indication -Hydra series

      Issue phenomenon: During the operation of the device, no red dot indication is found. Operation Guide: 1.Check whether the red light is operating normally ①.Open the left door of the device ②.Find the red light indicator mounting socket and check ...
    • How to connect the Air Purifier-X series

      1.Preparation ①. Consumable preparation One Laser X model device x 1,Air Purifier x 1,Phillips screwdriver x 1 ②. Debug software None 2.Operation step ①.Install the equipment air duct to the air inlet of the purifier Use a cross screwdriver to ...
    • Unboxing the X Series

      Unbox Step Cut cable tie. After removing the carton packaging, you can move the machine to your workbench. Remove the protective film. Remove all items included and remove the inner foam. Confirm all items. Disassemble the back box and add distilled ...
    • How to Install the Base for X Series

      Understand the Riser Base Assemble the raiser base
    • X Series Glossary

      Front and Rear View 1.Camera This component is used to checking the working status of working area. 2.Laser Head Laser beam comes out from it. 3.Touch Panel This component is used to control the machine, such as movement, run files. 4.PM2.5 Detector ...