Issue phenomenon:
During the operation of the device, no red dot indication is found.
Operation Guide:
1.Check if the lens is contaminated
- Use a dust-free cloth and cleaning fluid to clean the lens.
2.Re-import the calibration file
- In the Lightburn software, click "Window" and "Camera Control" to enable the camera control function. Select the camera name, usually "K35A2361".
- Note: Please check the camera screen to ensure that the camera is correctly selected and connected.
Right-click “Save Settings” and select “Import Camera Settings”.
The camera calibration file is located in the random USB flash drive. Please insert the USB flash drive into the computer and select the corresponding folder according to the device model.
- After importing the camera calibration file, click “Save Settings” to save the settings.
3.Exposure Adjustment
- The camera may cause unclear pages due to exposure issues, thus affecting the accuracy of camera recognition
- You can adjust the appropriate exposure to enhance the camera's recognition clarity.
- After importing the camera calibration file, click “Save Settings” to save the settings.