OneLaser Hydra Series Disassembly Guide for Transport

Device Disassembly Guide

Note:

When the width of elevator doors, room doors, or other passages is insufficient for the device to pass through, you can disassemble some of the outer shell components to reduce the width requirement for the device.

Personnel Requirements: A minimum of 4 people are required to assist in the handling process, please arrange personnel accordingly.

Preparation Work

One Laser Hydra series device *1

Hex wrench *1

Masking tape *1

Door cover key *1

Scissors *1

Disassembly Requirements

  • To facilitate subsequent handling and to reduce the weight of the device, we will disassemble components such as the device's door cover and processing platform. Please ensure that these removed parts are kept safely.
  • After the device and base are disassembled, the height is: Height: 77.5cm (including the height of the emergency stop and key switch), Width: 111cm.
  • If the height of 77.5cm is still not enough to pass through, you will need to remove the emergency stop switch and key switch. After removal, the height will be: 75cm.

Remove the device door cover and scrap bin

1.Use the key and hex wrench to remove the upper and lower front door covers of the device.

2.Remove the scrap bin.

Dismantle the emergency stop switch and key switch

NOTE:The method for removing the emergency stop switch and key switch is the same; here, only the operation for removing the emergency stop is demonstrated.

  1. Locate the emergency stop switch, flick the yellow lock, unlock it, and then remove the lower half of the emergency stop switch.

2.Counterclockwise rotate to unscrew the fixing ring and remove the upper half of the emergency stop switch.

Dismantle the honeycomb board and blade

1.Lower the platform to a certain height, use scissors to cut the ties that fix the honeycomb board.

2.Remove the honeycomb board and blade.

Note: When removing the honeycomb board, do not let it hit the laser head, as this may cause the optical path to deviate.

3.When closing the door cover, use masking tape to secure it and prevent the door cover from opening during transportation.

Separate the device from the base

1.The screws that fix the base are located inside the lower door cover on both the left and right sides of the device; you need to use the key to open the door cover.

2.Use the hex wrench to remove the screws that fix the base, as shown in the figure.


3.At this point, you can separate the device from the base. After separation, move the device into the room.

Note: It is best to prepare a handcart before flipping, and flip the device onto the cart for easier subsequent handling.

Restore the device

After the device is inside the room.

  1. Align the device with the base and tighten the fixing screws.
  2. Install the door cover, honeycomb board, key switch, and other accessories onto the device.


    • Related Articles

    • Maintenance Guide

      Optical Maintenance Tool Requirements Lens cleaner、Q-tip、hex key If the provided cleaning cleaner runs out, we recommend using absolute ethanol to clean the lens. To avoid damaging the lens coating, please do not use isopropyl alcohol. If the ...
    • OneLaser-Hydra The device emits abnormal light

      Issue Phenomenon The device emits abnormal light when it is turned on Fault Cause 1.Device motherboard port plug-in error The laser signal output port of the device is plugged into the wrong terminal Open the side door of the device and find the ...
    • How to connect the Air Purifier-X series

      1.Preparation ①. Consumable preparation One Laser X model device x 1,Air Purifier x 1,Phillips screwdriver x 1 ②. Debug software None 2.Operation step ①.Install the equipment air duct to the air inlet of the purifier Use a cross screwdriver to ...
    • How to switch between different focusing mirrors in One Laser Hydra

      Introduction The Hydra series of lasers come standard with a 2.5-inch focusing lens, with optional lenses available in 1.5-inch, 2.0-inch, and 4.0-inch sizes. This document will guide you on how to replace the different sizes of focusing lenses. ...
    • How to use One Laser Hydra camera

      ntroduction: The purpose of this document is to instruct users on how to connect, calibrate and use the One Laser Hydra series camera. Preparation USB cable*1, PC*1, USB flash drive*1, Lightburn software Connecting the machine and the camera 1. ...