Cabinet door rebounders replacement

Cabinet door rebounders replacement

Tools needed

2mm and 2.5mm Allen wrenches, new cabinet door rebounders

Note: In the process of replacing the accessories, the removed screws must be properly stored to avoid loss, so as not to affect the subsequent installation.

Replacement step

1. Disconnect the machine's main power cord, exhaust duct and other connecting parts.

2. Separate the machine from the raised platform base(Requires at least two people to lift and carry the machine)and remove the drawer.

3. Unscrew the screws (10 in total) on the right side support plate using an Allen wrench as shown below:

4. Then separate the right side support plate and front and rear door covers from the raised base

5. Using an Allen wrench, loosen and remove the cabinet door rebounder to be replaced. Then install and tighten the new door rebounder to secure it.

6. Re-assemble the elevated base, put the machine back on the elevated base, and connect the connecting parts such as the air extractor tube and the power cord to complete the replacement.

    • Related Articles

    • Camera Replacement

      Tools to prepare 1.5mm and 2mm Allen wrench, new camera module Remove camera ①. Open the front door cover and loosen the fixing screws on both sides of the camera cover, but there is no need to remove the screws. ②. Remove the camera cover. ③Unplug ...
    • Camera Replacement

      Tools Required 1.5mm and 2mm Allen wrench, new camera module Remove camera ①. Open the front door cover and loosen the fixing screws on both sides of the camera cover, but there is no need to remove the screws. ②. Remove the camera cover. ③. Unplug ...
    • Laser replacement

      Notes: 1.Before operation, the power must be disconnected, otherwise there is a risk of electric shock. 2.Please keep the screws that are removed properly to avoid losing them. Tools Required: Hex wrench,flathead screwdriver,Phillips screwdriver,door ...
    • Laser Power Supply Replacement

      Tools Required One screwdriver, Phillips screwdriver, door cover key The laser power supply is installed at the back of the machine. Note: The power must be disconnected before operation to avoid the risk of electric shock. 1. Glass Tube Laser Power ...
    • Control card replacement

      Tools that need to be prepared Door cover key, cross screwdriver Replacement steps 1. Disconnect the power supply of the device 2. Open the lower right door of the device 3. Disconnect all lines on the control board Note: Please take a photo and ...